ClaringtonQuotation for installation of small cold storageWhat is the design theory of

announcer:hp632HP195506591 release time:2022-03-04 22:10:21

The polyurethane insulation board used in the construction of cold storage shall be integral and continuous, top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.

The efficiency of the compressor is low, and the refrigerating capacity can not meet the load requirements of the warehouse: due to the long-term operation of the compressor, the cylinder sleeve, ring and other parts are seriously worn, the long-term cold storage installation, installation, construction, fruit preservation, medical cold storage and other brand products, the designated products are complete, the quality is guaranteed, and the sealing performance will be reduced accordingly with the increase of the matching clearance, The gas transmission coefficient of the compressor will also be reduced, and the refrigeration capacity will be reduced. When the refrigerating capacity is less than the heat load of the warehouse, the temperature of the warehouse will drop slowly.

Clarington.Frosting of evaporator will increase thermal resistance and decrease heat transfer coefficient. For the cooling fan, the air circulation cross-sectional area is reduced,ClaringtonLarge fruit fresh-keeping cold storage, the circulation resistance is increased, and the power consumption is increased. Therefore, defrost in time. Pay attention to the maintenance of the evaporator of the controlled atmosphere storage system. If the evaporator frosts it will affect the normal use of the controlled atmosphere storage. How to defrost in time? The current scheme of the controlled atmosphere storage includes: manual defrosting, which is simple and easy

No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.

.The drainage at the outlet of the cooling fan, the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.

2 - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.

Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.


ClaringtonQuotation for installation of small cold storageWhat is the design theory of



Compression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.

The startup of the air-cooled refrigerator unit shall depend on whether the rotation direction of the fan is correct. If the forward rotation can be started for operation, the reverse rotation indicates that the power wiring is reversed, and the phase sequence must be replaced before startup.

The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.

original.Airtight construction of quick freezing storehouse: the modified atmosphere fresh-keeping storehouse is developed on the basis of the traditional high-temperature fresh-keeping storehouse, which has the & ldquo; Refrigeration & rdquo; Function,ClaringtonDesign and installation of fruit cold storage, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage, complete products, excellent quality and favorable price. There are also & ldquo; Air conditioning & rdquo; Function; However, the quick freezing storehouse is not a simple superposition of ordinary high temperature storehouse and air conditioning equipment. In order to adjust the gas composition in the storehouse quickly, it is necessary to ensure that the quick freezing storehouse has good air tightness. This has been confirmed by the theoretical research and a large number of practical experience of quick freezing warehouse.

Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.

The installation of top warehouse plate should be carried out alternately with the installation of wall plate and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, if there are supporting beams columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.


ClaringtonQuotation for installation of small cold storageWhat is the design theory of



Cold storage has good fire and flame resistance. After adding flame retardant, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular,ClaringtonCold storage installation, it can be closed as a whole after fire prevention treatment to form non combustible products.

Quotation sheet.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, the end steel sheet at the overlap with the wall plate shall be disconnected for 50mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be 300mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, the tightness of the quick freezing warehouse door, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.

Clarington.The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in 2-5 days, The library body can be combined, separated or increased or decreased according to the needs of users.

The combined cold storage door starts frequently or does not start for a long time, or stops before the storage temperature reaches.

During the use of cold storage, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plate, which will seriously reduce the local thermal insulation performance of the storage body.