Niagara-FallsCold storage installationThe precautions for use are mainly divided into three points

announcer:hp632HP195506591 release time:2022-03-05 12:03:22

The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with 0.5 color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be 300mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.

During production in the production workshop, the unit weight of Pu warehouse board shall not be less than the unit weight required by the project, not less than 40 & plusmn; 2kg/m3.

Niagara-Falls.Ice cubes are always available in the cold storage. For small cold storage, the cost of using standby power supply or generator set is too high and the cost performance is low. In this case, some ice cubes must be always available in the cold storage. In case of power failure or refrigeration equipment failure, ice cubes can be used to maintain the temperature in the cold storage.

Because polyurethane sheet has excellent thermal insulation performance it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.

.The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.

During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be 100 cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.

Polyurethane with good fire resistance and flame retardancy is a kind of refractory and self extinguishing material after adding flame retardant. In case of fire, it can be carbonized, unlike flow burning and flashover like extruded board, the size of the refrigerator or the storage capacity (size, storage capacity, ton,Niagara-FallsMedical biological cold storage, cubic meter, frame, box); What products are stored in the built cold storage? The actual storage temperature, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials, such as refrigeration compressors, refrigeration units, industrial cooling fans / pipe slots thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.

When adjusting the station,Niagara-FallsCold storage transfer, each outlet pipe shall be sawn into a 45 degree inclined mouth to the bottom, and the inlet pipe shall be 4 points of the pipe diameter of the adjusting station.

Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, pay special attention to the operation state of the system and adjust the liquid supply and condensation temperature of the system in time.

agent.We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities,Niagara-FallsCold storage board installation, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R11 gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.

Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.

The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.


Niagara-FallsCold storage installationThe precautions for use are mainly divided into three points



The selection of equipment for the construction of equipment cold storage is closely related to the size, type and budget of the cold storage.

total cost.Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; amp; gt; 100 mm; The electrical box can be fixed on the building wall or on the angle steel frame.

The cooler on the refrigeration unit is very easy to be dirty, so it should be cleaned on time according to the specific situation. To maintain stable heat conduction and practical effect. Good heat removal and cooling. There is no need to accumulate dirt around the refrigeration unit.

Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.

Niagara-Falls.The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, rapid and movable, but the project cost is relatively high.

Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO9002 quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).