DurhamEnergy saving design of cold storageDiligent in maintenance and preparedness

announcer:hp632HP195506591 release time:2022-01-18 23:15:28

We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage construction, fruit preservation cold storage medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated,DurhamInstallation of fresh-keeping cold storage, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R11 gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious,DurhamFruit cold storage temperature, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is,DurhamInstallation price of fresh-keeping cold storage, to form a vapor barrier layer.

Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, good permeability to water vapor, foam holes, disconnected and closed porosity of more than 95%. It is a dense microporous foam material, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.

Durham.The ventilation device is adopted, which also produces heat exchange with the outside air, resulting in & amp; amp; quot; Heat leakage & amp; amp; quot;, Energy is wasted so an air scrubber is required. Washing, amino, activated carbon, sieve, etc.

In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (100mm thick) has a very large span of 3M, and the polyurethane top storage plate (100mm thick) has a span of 5m.

.Secondly, the multi work operation at night can be selected if possible. When working at night, the external temperature is low, the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.

With the development of the times, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need it in the production process of cold storage

With the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?


DurhamEnergy saving design of cold storageDiligent in maintenance and preparedness



Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.

The gap between the cooling fan and the storage plate shall be greater than the thickness of the cooling fan.

1 - precautions for floor installation of cold storage: the floor shall be installed flat the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).

Word of mouth recommendation.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.


DurhamEnergy saving design of cold storageDiligent in maintenance and preparedness



Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, PVC color steel plate and stainless steel plate. The advantage of this is that it can prevent refrigeration, because the temperature difference inside and outside the board is large, and the temperature will disperse, which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.

Welcome to inquire.The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, bleach, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below 50 degrees Celsius. Then, according to the volume of 50~100 grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, it is necessary to consider the condensation pressure and other related problems of the unit, increase the proportion of outdoor cold air, and achieve the effect of energy saving.

Grasp the key points. Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, when the water vapor with high indoor temperature migrates outdoors, it is impossible to condense in the wall due to the obstruction of the cold storage.

Durham.Goods in and out frequently, throughput

Cold storage has good fire and flame resistance. After adding flame retardant polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.

The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.