PetersburgWhich is a good cold storage installationQuotation

announcer:hp632HP195506591 release time:2022-03-05 19:03:22

The ultrasonic town is a patented technology with a shaped energy cover, which increases the effective humidification amount by 50-70% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?

Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage,PetersburgFruit fresh-keeping cold storage installation project, so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room,PetersburgCold storage installation, the attic on the top floor can be built into the ice making room, cold storage board, as an important structure of cold storage, is also increasing. Because cold storage is different from other ordinary cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.

.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be 10 ~ 12 seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; 1TR time relay is broken (relay unit).

The medical cold storage has been widely used in the industry. For the use of the medical cold storage project, we must combine the performance of the product and store it according to the temperature and humidity required by the product. The automatic temperature box also needs to be used outside the product cold storage. At the same time, the management personnel must be familiar with the operation steps of the medical cold storage project.

Floor insulation of small cold storage the structure of small cold storage is usually called surface, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.


PetersburgWhich is a good cold storage installationQuotation



During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be 10mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the 10mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.

When installing and splicing the storeboard in the fresh-keeping storehouse, it needs to be tightly sewn to ensure the tightness; The fresh-keeping storehouse will discharge water during operation, and the drainage pipe should be installed in a place that can circulate; An anti-collision barrier shall be installed around the door of the fresh-keeping storehouse to prevent the door from being damaged by impact. To play an eye-catching role, the fresh-keeping storehouse shall be equipped with emergency lights, alarm devices and safety channels to facilitate self rescue or alarm for help in case of emergencies.

The quantity is large, and a special tally room (area) is set according to the needs of production and operation. The temperature of the tally area is usually controlled at 0 ~ + 7 ℃.

Production department.During operation, the water temperature will still drop, and the humidification amount will be reduced by 70% at 5 ℃.

Where do you need to build the refrigerator, the size of the refrigerator or the storage capacity (size, storage capacity, ton, cubic meter frame, storage time and setting temperature can be indicated by specific regulations; If your cold storage becomes larger you need to master your individual storage volume, the temperature of goods in and out of the warehouse, the frequency of opening and closing the door, etc. If this is clear, it is the selection of raw materials such as refrigeration compressors, refrigeration units, industrial cooling fans / pipe slots, thermal insulation materials, coolers, doors, temperatures and other refrigeration equipment.

Polyurethane foam: This is also a very common cold storage material. It has strong thermal insulation effect and strong mechanical strength. Now it is widely used and has a good application prospect.


PetersburgWhich is a good cold storage installationQuotation



Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; amp; gt; 100 mm; The electrical box can be fixed on the building wall or on the angle steel frame.

For more, please check.Cold storage has strong stability. Polyurethane foam technology makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is under the unfavorable local temperature and humidity conditions, the characteristics of the cold storage still do not separate and fall off from the carrier layer and remain stable under normal conditions.

Evaporation temperature the sweating temperature of the refrigeration in the wafer machine needs to be lower than the air temperature in order to transfer heat from the engine room to the refrigerant. Usually, the temperature difference of room air conditioner is between 12C and 14C. If the temperature difference cannot be maintained due to adverse factors, the operation energy consumption will increase.

When opening and drilling is required for the top warehouse plate or wall plate,PetersburgInstallation of 100t vegetable fresh-keeping cold storage, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of 300mm and 150mm outside.

Petersburg.The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.

Cold storage construction: which one is suitable for you? Which one is suitable for you?

The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.