There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is 0.5mm and 0mm, without color requirements; The thickness of salted steel plate is 0.5mm, without color requirements; The thickness of PE paint baking board is 0.5mm, 0.8mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the 150 mm storage plate is 150 mm, and the thickness of the vertical plate is 160 mm and 100 mm, which is suitable for the insulation conditions of - 25 ℃ ~ - 45 ℃; 100mm storage plate: the thickness of the ceiling plate is 100mm and the thickness of the vertical plate is 110mm, which is suitable for the thermal insulation conditions of 0 ℃ ~ - 25 ℃. The thickness of the ceiling plate and the vertical plate of 60mm storage plate is 60mm which is suitable for the thermal insulation conditions above 0 ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = 900mm, heaven and earth plate width WB = 980mm, vertical angle plate W1 = 790mm, W2 = 840mm,ManhattanDesign and installation price of cold storage, W3 = 740mm and W4 = 880. The dimensions of non-standard plates are different from those of Wa, WB and W4.

The temperature is too high, the condenser is blocked in the cold storage, the compressor is overloaded there is a lack of refrigerant, the low pressure is too low, the air intake is too large, and the vibration of the shaft.

Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.

.The selection of cold storage is very important for cold storage, because cold storage is different from ordinary cold storage. The temperature in cold storage is usually low, and the air temperature, humidity and environmental requirements are relatively high. When selecting cold storage, attention must be paid to the selection of cold storage with better temperature. If the selection of cold storage is not good, the temperature in the cold storage is difficult to, which is easy to cause the deterioration of products in the cold storage, or the refrigeration compressor in the cold storage often works, wasting more resources and increasing the cost.

Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is 35 ~ 40kg / m3, the thermal conductivity is only 0.018 ~ 0.024w / (m.k), but it also has a great relationship with the proper daily management and maintenance after the installation of the cold storage. Many times, people often ignore the latter point. In daily life, as long as we maintain and maintain the cold storage regularly, we can greatly improve the service life of the cold storage and reduce the cost.


ManhattanWhich one do you want for cold storage installationThe golden period of brand building



Frozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.

The air suction surface of the condenser shall be kept more than 400mm away from the wall, and the air outlet shall be kept more than 3m away from obstacles.

In order to maintain a constant low temperature in the cold storage, attention should be paid to the installation of cold storage panels in Guizhou: the floor, wall and flat roof of the cold storage are laid with a certain thickness of thermal insulation materials to reduce the incoming heat from the outside. In order to reduce the absorption of solar radiation the surface of the external wall of the cold storage is painted white or light color. Therefore, cold storage building is different from general industrial and civil buildings, and has its unique structure. Cold storage buildings should prevent the entry of air and the diffusion of water vapor.

Standard requirements.During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be 100 cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.

The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.

During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.


ManhattanWhich one do you want for cold storage installationThe golden period of brand building



The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, bleach, formalin, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below 50 degrees Celsius. Then, according to the volume of 50~100 grams per cubic meter volume of the frozen storeroom, and the blower is started intermittently, so that the vinegar evaporates and flows in the storehouse, which makes the vinegar absorb a lot of fish smell.

Good reputation.For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.

After evacuation, fill the refrigerant into the liquid storage to 70% of the standard filling volume & mdash; 80% by weight, then run the compressor and add gas from low pressure to sufficient volume.

Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and in the production process of cold storage, there will be no condensation in the cold storage of the plant. Condensation inside the cold storage or inside the insulation layer is harmful. Irreversible damage or deformation occurs in the new external insulation, and the external surface temperature of the external wall changes sharply. For example, the insulation and sound insulation effects of polyurethane insulation board are relatively good, which can be used in many industries. As we all know, the cold storage has great requirements for the thermal insulation effect of building materials. If the thermal insulation effect of building materials is not good, the cold storage will consume more energy during operation, and can not guarantee a good refrigeration effect. The performance of polyurethane insulation board meets the construction requirements of cold storage, so a large number of polyurethane insulation boards need to be used in the construction of general cold storage. Next, let's understand the physical properties of polyurethane insulation board.

Manhattan.Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, focus on the connection of each pipeline and valve, repair the found part,ManhattanInstallation works of fresh-keeping cold storage, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.

Cold storage has good fire and flame resistance. After adding flame retardant,ManhattanHow much is the charge for cold storage installation, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, unlike flow burning and flashover like extruded board, it can be closed as a whole after fire prevention treatment to form non combustible products.