SuriWhich is a good medical cold storageMarket prices may still fall

announcer:hp632HP195506591 release time:2022-02-19 09:00:05

In the cold storage project, the selection of cold storage is related to the overall operation of cold storage in the future. The selection of high-quality cold storage is conducive to the use and maintenance of cold storage. This requires us to inquire more about the warehouse board for cold storage engineering. Before the construction of cold storage project, we should first realize the temperature requirements of cold storage and the importance of cold storage to cold storage. Because the cold storage project has high environmental requirements such as temperature, attention should be paid to the performance and material of the cold storage board when selecting the cold storage board.

During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, 10cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use 12cm or 15cm thick library board. When you budget the cold storage project,SuriInstallation of small fruit cold storage, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to the regulations, the cold storage shall be distributed

Suri.The warehouse shall be equipped with emergency lighting, which can save themselves or call the police for help.

Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the refrigerant flow is too large, the evaporation pressure and evaporation temperature also increase, and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked, the refrigeration capacity of the system will also decrease, and the decline rate of warehouse temperature will also slow down.

.Install the temporary lighting facilities in the warehouse, install and arrange the construction electrical equipment, and do a good job in rain proof, moisture-proof anti-collision, anti binding and other safety protection.

Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, medical cold storage, strict testing, quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then, the water vapor in the cold storage is easy to condense, and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water its nature will be greatly reduced. Therefore, which increases the effective humidification amount by 50-70% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?


SuriWhich is a good medical cold storageMarket prices may still fall



The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.

The whole equipment is clean and the environment is clean.

The exhaust temperature of the compressor equipment is often. When the season changes and the temperature difference changes greatly, pay attention to it. If the machine is abnormal, it needs to be checked in time.

market.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.

Strong deformation resistance not easy to crack, smooth, stable and safe. Polyurethane material has stable porosity structure and basically closed pore structure. It not only has excellent thermal insulation performance, but also has good freeze-thaw resistance and sound absorption performance. Under normal service and maintenance conditions, the life expectancy of rigid foam polyurethane insulation can reach more than 30 years. During the structural life period, it can reach the unit price of dry, wet or electric corrosion under normal service conditions, while the unit price of insect, fungus or algae foam material is higher than other traditional insulation materials, but heating will increase the cost and the cooling cost will be greatly reduced.

Improper adjustment or blockage of throttle valve, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the evaporation pressure and evaporation temperature also increase, and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked, the refrigerant flow will also decrease, the refrigeration capacity of the system will also decrease, and the decline rate of warehouse temperature will also slow down.


SuriWhich is a good medical cold storageMarket prices may still fall



It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is 15-20 degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even if

How many?.The ultrasonic town is a patented technology with a shaped energy cover, which increases the effective humidification amount by 50-70% per hour. What are the reasonable aspects of the design of the quick freezing warehouse?

The location temperature, temperature difference and other main parameters of fresh-keeping warehouse equipment wholesale shall be set according to the specific situation of the frozen warehouse, and the main parameters cannot be changed at will. All kinds of cold storage installation, cold storage installation, cold storage construction fruit preservation cold storage,SuriHow much does it cost to install a small cold storage, medical cold storage formal qualification, welcome to telephone inquiry, sincerely invite cooperation! The freezer has been customized according to the customer's regulations in the original factory. After mastering the performance parameters of the freezer, set various main parameters on the board.

Generally,SuriCold storage unit installation, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.

Suri.When the cold storage is used for the first time or shut down for a long time, it is strictly prohibited to stack goods in the warehouse. The warehouse must be slowly reduced to the required temperature. For the low-temperature warehouse, it needs to be cooled in stages to avoid sudden changes in the temperature difference inside and outside the warehouse, resulting in the warehouse body.

Compression refrigerator is commonly used, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device, it can be divided into direct cooling and indirect cooling. Direct cooling the evaporation pipe is installed in the refrigerated warehouse. When the liquid coolant passes through the evaporation pipe, it will directly absorb the heat in the warehouse and cool down.

Cold storage plate features: good thermal insulation performance, light weight, high strength, corrosion resistance, anti-aging, beautiful appearance.