AucklandInstallation cost of small freezerHow to improve market competitiveness

announcer:hp632HP195506591 release time:2022-01-10 19:40:18

General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)

During production in the production workshop, the unit weight of Pu warehouse board shall not be less than the unit weight required by the project, not less than 40 & plusmn; 2kg/m3.

Auckland.If the controlled atmosphere storage works continuously for more than 2000h, medium maintenance shall be carried out. The condenser, evaporator and cooling exhaust pipe shall be overhauled once a month. The maintenance contents are as follows: the condenser, evaporator and cooling drain pipe are cleaned and adjusted, the cooling water distribution device is cleaned and adjusted, the brine distribution device is cleaned and adjusted, the cooling drain pipe is repaired and the pipe leakage fault is eliminated.

Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage is better

.The construction structure of structural cold storage can be brick concrete structure or steel structure, which can be determined according to their own budget and actual needs. At present, most cold storages are constructed with single-layer steel structure and are equipped with combined thermal insulation storage body, unloading platform, system, pipeline system, etc. according to the actual needs of cold storage circulation.

On the basis of cold storage and preservation, the quick-frozen warehouse increases the regulation of gas composition, inhibits the respiration of fruits and vegetables, delays their metabolic process, better maintains the freshness and commercial quality of fruits and vegetables, and prolongs the storage period and shelf life of fruits and vegetables. Generally, controlled atmosphere storage of fruits can prolong the storage period by 2 & mdash; Three times or more. OK, what is the standard of quick freezing warehouse?

Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, good permeability to water vapor, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.


AucklandInstallation cost of small freezerHow to improve market competitiveness



After the cold storage at the corner is installed, the next cold storage can be installed along the direction of the corner. Adopt the similar installation of Zhang cold storage to install the thermal insulation board of the storage. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, advanced technology, strict testing, more affordable price and more preferential. Welcome to consult. Pay attention to its compactness and continuous uniformity.

The exhaust pipe and return pipe shall have a constant slope. When the condenser is higher than the compressor, the exhaust pipe shall slope towards the condenser and a liquid ring shall be installed at the exhaust port of the compressor. Prevent the gas from cooling and liquefying back to the high-pressure exhaust port after shutdown, and cause liquid compression during restart.

Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time,AucklandHow much is the charge for cold storage installation, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification, with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts 10cm thick cold storage plate, 12cm or 15cm thick cold storage board is generally used for ultra-low temperature cold storage and freeze-cleaning cold storage; Another kind of cold storage can be sprayed with polyurethane spray paint and polyurethane foam, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance,AucklandCold storage professional installation, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance, but the cost is low.

Packaging strategy.Installation of refrigeration equipment. The refrigeration system of the cold storage includes evaporator and units outside the cold storage. All equipment shall be installed in accordance with the construction specifications and corresponding protection measures shall be taken for the installed equipment.

However, long-term continuous operation will inevitably lead to equipment aging, so reasonable maintenance is particularly important.

Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be 10 ~ 12 seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; 1TR time relay is broken (relay unit).


AucklandInstallation cost of small freezerHow to improve market competitiveness



Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, good permeability to water vapor, foam holes disconnected and closed porosity of more than 95%. It is a dense microporous foam material, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.

Excellent service.Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit,AucklandHow much is the charge for installing cold storage, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.

Whether the warehouse can drill through the wall. The construction and installation of cold storage shall be like the installation of air conditioner, and the external unit shall be connected with the unit in the cold storage.

The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.

Auckland.Cold storage design segmentation: several different partitions shall be reasonably planned and divided according to purpose and temperature. For example: processing room, sorting room, quick freezing room, refrigeration room, channel, unloading platform, etc.

Cold storage has good fire and flame resistance. After adding flame retardant, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.

The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.