burnabyCold storage installation worksComprehensive maintenance support

announcer:hp632HP195506591 release time:2022-02-21 17:00:08

Commissioning cold storage. After all parts of the cold storage are installed and connected, the cold storage can be started for cold storage commissioning. According to the needs of customers, adjust the value of the cold storage, the cold storage can reach the predetermined temperature, the cooling speed and the operation of the cold storage are normal, and the cold storage can be delivered for use. The cold storage installation unit shall also provide the cold storage user with training on cold storage use and management knowledge, as well as some after-sales training.

What should be considered in building a cold storage? In these aspects, food cold storage is a systematic project of artificial refrigeration to ensure food quality and reduce food decay in a low-temperature environment. Refrigeration technology affects the design of food cold storage, meets the needs of refrigeration technology, convenient production energy saving and cost reduction. What problems should be considered in the construction of food cold storage?

burnaby.The water-cooled cold storage shall keep the cooling water tower clean and keep the air around the water tower circulating with low temperature, so as to avoid sundries from entering the cooling tower and reduce the heat dissipation efficiency.

Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.

.When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.

Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used large construction equipment is required and the construction period is long.

The spacing of pull rivets at inner and outer corners is 300mm and 200mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.


burnabyCold storage installation worksComprehensive maintenance support



It is built in the room. There shall be excellent drainage pipe standards around the cold storage, the soil temperature shall be low, there shall be interlayer under the cold storage, and good natural ventilation shall be maintained. Maintaining dryness is very important for the cold storage. In addition, before the construction of the cold storage, the phase electricity of the relative volume shall be built according to the output power of the refrigeration unit. If the cold storage is water-cooled and radiating, the tap water pipeline shall be paved and the FRP cooling tower shall be built.

The selection of the refrigeration system of the controlled atmosphere storage is mainly the selection of compressor and evaporator. The refrigeration system is the core of the controlled atmosphere storage, which is mainly composed of compression system, condensation system, evaporation system and regulating valve. In addition, duct and instrument. The whole refrigeration system is a sealed circulating circuit in which the refrigerant circulates, The compressor is the heart of the refrigeration system, water cooling and the combination of air and water. Air cooling is only used in the refrigeration equipment of small-scale air-conditioned storage. The role of the evaporator is to provide cooling capacity to the air-conditioned storage. The evaporator is installed in the air-conditioned storage. The blower blows the cooled air to all parts of the storage. The air duct of large-scale air-conditioned storage is commonly connected with the evaporator to extend the air supply distance, Make the storage temperature drop and even.

We should implement regular maintenance and daily maintenance, professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, large quantity excellent quality and low price, strong and durable fire resistance - Waterproof - high temperature resistance, safe and reliable, and maintain the operation rate of the compressor.

investment.The construction structure of structural cold storage can be brick concrete structure or steel structure, which can be determined according to their own budget and actual needs. At present, most cold storages are constructed with single-layer steel structure, unloading platform, refrigeration system, system, pipeline system, etc. according to the actual needs of cold storage circulation.

Core tip: in the cold storage project, and is not prone to failure, convenient use and management and long service life.

With the development of the times,burnabyFruit and vegetable cold storage,burnabyDesign and installation of small cold storage, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need it in the production process of cold storage


burnabyCold storage installation worksComprehensive maintenance support



Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally,burnabyCold storage and preservation of vegetables, the refrigeration oil and drying filter shall be replaced 30 times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.

Test method.Various construction materials, such as material certificate, test report and stage acceptance record, shall be carried out simultaneously with the project construction, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, and actively cooperate with the owner in design change and technical negotiation.

To the purpose of cooling down.

The efficiency of the compressor is low, and the refrigerating capacity can not meet the load requirements of the warehouse: due to the long-term operation of the compressor, the cylinder sleeve, ring and other parts are seriously worn, the long-term cold storage installation, installation, construction, fruit preservation, medical cold storage and other brand products, the designated products are complete, the quality is guaranteed, and the sealing performance will be reduced accordingly with the increase of the matching clearance, The gas transmission coefficient of the compressor will also be reduced, and the refrigeration capacity will be reduced. When the refrigerating capacity is less than the heat load of the warehouse the temperature of the warehouse will drop slowly.

burnaby.At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.

8. This shows the importance of regular oil discharge, descaling and air discharge in the refrigeration system of cold storage.

When installing the polyurethane insulation board, the adhesion between the panel of the polyurethane insulation board and the thermal insulation material is short and often high.